Abstract
References
1.W. L. Nyborg, “Heat generation by ultrasound in a relaxing medium,” J. Acoust. Soc. Am. 70, 310-312 (1981). 2.T. L. Szabo, “Time domain wave equations for lossy media obeying a frequency power law,” J. Acoust. Soc. Am. 96, 491-500 (1994). 3.D. J. Powell, J. Mould, and G. L. Wojcik, “Dielectric and mechanical absorption mechanisms for time and frequency domain transducer modeling,” in Proc. IEEE Ultrason. Symp., 1019-1027 (1998). 4.K. L. Gentry, M. L. Palmeri, N. Sachedina, and S. W. smith, “Finite element analysis of temperature rise from an integrated 3-D intracardiac echo and ultrasound ablation transducer,” in Proc. IEEE Ultrason. Symp. 122-125 (2004). 5.S. Wang, V. Frenkel, and V. Zderic, “Optimization of pulsed focused ultrasound exposures for hyperthermia applications,” J. Acoust. Soc. Am. 130, 599-609 (2011). 6.R. Samanipour, M. Maerefat, and H. R. Nejad, “Numerical study of the effect of ultrasound frequency on temperature distribution in layered tissue,” J. Therm. Biolo. 38, 287-293 (2013). 7.P. Gélat, G. T. Haar, and N. Saffari, “A comparison of methods for focusing the field of a HIFU array transducer through human ribs,” Phys. Med. Biol. 59, 3139-3171 (2014). 8.A. C. S. Parr, R. L. O’Leary, G. Hayward, and G. Smillie, “Improving the thermal stability of 1-3 piezoelectric composite transducers manufactured using thermally conductive polymeric fillers,” in Proc. IEEE Ultrason. Symp. 362-365 (2003). 9.A. C. S. Parr, R. L. O’Leary, and G. Hayward, “Improving the thermal stability of 1-3 piezoelectric composite transducers,” IEEE Trans. Ultrason, Ferroelect. Freq. Contr. 52, 550-563 (2005). 10.J. L. Butler, A. L. Butler, and S. C. Butler, “Thermal model for piezoelectric transducers (L),” J. Acoust. Soc. Am. 132, 2161-2164 (2012). 11.R. Ramesh, R. K. Kumar, and T. K. V. Kumar, “Heat generation in 1-3 piezoceramic-polymer composites,” J. Electroceram. 30, 251-257 (2013). 12.A. S. Ergun, S. Barnes, and E. Gardner, “An assessment of the thermal efficiency of capacitive micromachined ultrasonic transducers,” in Proc. IEEE Ultrason. Symp. 420-430 (2007). 13.P. Vasiljev, D. Mazeika, and S. Borodinas, “Minimizing heat generation in a piezoelectric Langevin transducer,” in Proc. IEEE Ultrason. Symp. 2714-2717 (2012). 14.L. E. Kinsler, A. R. Frey, A. B. Coppens, and J. V. Sanders, Fundamentals of Acoustics, Fourth Edition (John Wiley & Sons, New York, 2000), pp. 211-212, 529-531, 508-509. 15.J. H. Lienhard IV and J. H. Lienhard V, A Heat Transfer Textbook, Third Edition (Courier Dover Publications, New York, 2008), pp. 54-56.
Information
- Publisher :The Acoustical Society of Korea
- Publisher(Ko) :한국음향학회
- Journal Title :The Journal of the Acoustical Society of Korea
- Journal Title(Ko) :한국음향학회지
- Volume : 34
- No :3
- Pages :210-218
- Received Date : 2015-03-03
- Revised Date : 2015-04-04
- Accepted Date : 2015-04-28
- DOI :https://doi.org/10.7776/ASK.2015.34.3.210



The Journal of the Acoustical Society of Korea









