All Issue

2013 Vol.32, Issue 5 Preview Page
30 September 2013. pp. 393-401
Abstract
References
1
1.A. Nguyen-Dinh, P. Mauchap, N. Felx, R. Dufait, P. Auclair, and A. Flesch, “Integrated mechanism based multiplaned/3D ultrasonic imaging probes,” in Proc. IEEE Ultrason. Symp., 1147-1150 (2001).
2
2.R. Canals, G. Lamarque, and P. Chatain, “Volumetric ultrasound system for left ventricle motion imaging,” IEEE Trans. Ultrason, Ferroelect., Freq. Contr. 46, 1527-1538 (1999).
3
3.H. Eun, S. Lee, and Y. Roh, “Design and fabrication of a 3-dimensional diagnostic ultrasonic probe” (in Korean), J. Acous. Soc. Kr. 21, 766-771 (2002).
4
4.S. W. Smith, G. E. Trahey, and O. T. von Ramm, “Two- dimensional arrays for medical ultrasound,” in Proc. IEEE Ultrason. Symp. 628-628 (1991).
5
5.R. L. Goldberg and S. W. Smith, “Multilayer piezoelectric ceramics for two-dimensional array transducers,” IEEE Trans. Ultrason,, Ferroelect., Freq. Contr. 41, 761-771 (1994).
6
6.S. S. Brunke and G. R. Lockwood, “Braod-bandwidth radiation pattern of sparse two-dimensional vernier arrays,” IEEE Trans. Ultrason,, Ferroelect., Freq. Contr. 44, 1101- 1109 (1997).
7
7.P. K. Weber, R. M. Schmitt, B. D. Tylkowksi, and J. Steck, “Optimization of random sparse 2-D transducer arrays for 3-D electronic beam steering and focusing,” in Proc. IEEE Ultrason. Symp. 1503-1506 (1994).
8
8.D.F. Lemmerhirt, X. Cheng, R. D. White, C. A. Rich, M. Zhang, J. B. Fowlkes, and O. D. Kripfgans, “A 32 X 32 capacitive micromachined ultrasonic transducer arrays manufactured in standard CMOS,” IEEE Trans. Ultrason, Ferroelect., Freq. Contr. 59, 1266-1271 (2012).
9
9.W. Lee and Y. Roh, “New design of the kerfs of an ultrasonic two-dimensional array transducer to minimize cross-talk,” Jpn. J. Appl. Phys. 49, 07HD06, 2010.
10
10.W. Lee and Y. Roh, “Design and fabrication of a 1.75D ultrasonic transducer” (in Korean), J. Acoust. Soc. Kr. 32, 199-207 (2013).
11
11.R. E. Davidsen and S. W. Smith, “Two-dimensional arrays for medical ultrasound using multilayer flexible circuit interconnection,” IEEE Trans. Ultrason,, Ferroelect., Freq. Contr. 45, 338-348 (1998).
12
12.L. Daane and M. Greenstein, “A demountable interconnect system for a 50 X 50 ultrasonic imaging transducer array,” IEEE Trans. Ultrason,, Ferroelect., Freq. Contr. 44, 978-982 (1997).
13
13.N. N. Abboud, G. L. Wojcik, D. K. Vaughan, J. Mould, D. J. Powell, and L. Nikodym, “Finite element modeling for ultrasonic transducers,” in Proc. SPIE Int. Symp. Medical Imaging, (1998).
Information
  • Publisher :The Acoustical Society of Korea
  • Publisher(Ko) :한국음향학회
  • Journal Title :The Journal of the Acoustical Society of Korea
  • Journal Title(Ko) :한국음향학회지
  • Volume : 32
  • No :5
  • Pages :393-401
  • Received Date : 2013-04-11
  • Revised Date : 2013-06-05
  • Accepted Date : 2013-06-17